Above Ground Swimming Pool Electrical Code
Your swimming pool equipment may have other needs for electricity.
Above ground swimming pool electrical code. All electrical installations in walls or decks close to swimming pools must follow these requirements. Local set back rules must be followed. 2008 national electrical code 2010 residental code of new york state permanently installed swimming pools. Cord length for a pump motor is 3 except for storable pools.
National electrical code definition are those pools that are constructed or partially in the ground all others pools capable of holding water with a depth greater than 42 inches. Metal parts greater than 12 ft vertically above the maximum water level are not required to be bonded 680 26 b 7 ex 3. Top 10 major code changes to look out for in the nec 2017. Does your swimming pool have any other electrical needs.
In many communities above ground pools must be at least 10 feet from buildings fences and property lines. For added protection of all new pool installations the 2017 nec national electrical code article 680 has been amended. Utility power lines that run over a pool or spa must be at least 22 5 feet above the water level or base of a diving platform. Above ground pools are not allowed in the front yard.
If the pool is an above ground and is considered storable then the following codes apply. Thanks for your electrical question sue. Metal parts greater than 5 ft horizontally from the inside walls of the pool are not required to be bonded 680 26 b 7 ex 2. Add ons like ozonators ionizers and salt chlorine generators require electricity.
The nec mandates that overhanging electrical cords must be kept at a safe height from the ground and people s heads for utility power lines that hang over a pool or spa they must have a clearance of 22 5 feet over the water level deck or diving platform communications cables must be at least 10 feet above. 1 pool pump receptacle outlet and wiring methods a. Some communities may also forbid swimming pools in side yards. 10 horizontal from the pool wall.
Pools cannot be placed over any underground sewer water or utility lines. 680 9 overhead wire clearance is min. A typical above ground pool pump will require a 20 amp breaker and use 12 gauge wire to deliver the electricity. All 125 volt outlets or receptacles within 2o feet of the inside walls of a pool require gfci protection.
2017 national electrical code sps 316 swimming pool wiring nec article 680 680 5 gfci s may be either circuit breakers or receptacle type. If electric is required to supply a pool filter pump motor or a pool low voltage underwater light fixture listed and labeled for us with a storable pool that is 42 deep or less nec article 680 4 then your pool equipment must be served by a gfci protected.